DV50 Adroit (Integral CO2 Sensor) is a ventilation unit with state-of-the-art technology suitable for small houses up to 80 m2. Designed to provide essential ventilation and to save you money through its intelligent heat recovery facility, this system provides a cost-effective and environmentally friendly option for residential applications.
Control your indoor air environment at home or on the go via the Adroit 'Cloud' by smartphone, tablet, or PC.
Having the latest, low energy EC fan technology, the DV50 Adroit (Integral CO2 Sensor) complies with the ErP 2016 and the proposed ErP 2018 standards. The unit comes with an outstanding 5 years warranty*, is SAP Appendix Q recognised.
The electrical power rating of the MVHR unit refers to the highest power input allowed to flow through it to achieve its maximum air flow rate. Energy-efficient ventilation systems ensure that fresh air is supplied to the dwelling without unnecessary energy consumption. By minimizing energy consumption, the MVHR solution contributes to a lower carbon footprint, supporting global efforts to tackle climate change.
- Supply air fan power: 0.043kW, 0.32A, EC
- Extract air fan power: 0.043kW, 0.32A, EC
- Electrical power input at maximum flow: 96W
KEY FEATURES:
- Extracts up to 205 m3/hr @ 100 Pa
- Up to 90% thermal efficiency
- Automatic, 100% bypass
- Triple filter design - ISO 16890 compliant
- Internal carbon dioxide sensor
- 5 year warranty*
- 'A' energy rating
- Internet control by smartphone, tablet, or PC
- Passive house certified
KEY BENEFITS:
- Supply and extract air ventilation with heat recovery
- Galvanised steel, powder coated double-skin casing
- Auto cut-out switch for extra safety
- BMS connection via MODBUS or KNX (optional)
- Boost operation with timer
- On demand control via room or duct sensor options
- Complies with the NHBC criteria and ErP 2016 standards
- SAP Appendix Q recognised. Meets building regulations
- Integral carbon dioxide sensor as standard
- Optional LCD digital controller with four independent environmental profiles
- Optional manual four speed controller
- Optional smart frost protection
- Optional built-in electric post heater (Part number: 90001273EPH; to be ordered via Quick Order Pad)
COMPONENTS WITH THE LATEST TECHNOLOGY
The DV50 Adroit (Integral CO2 Sensor) includes an easily removable, plastic heat exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air with thermal efficiency up to 90%. At no point do the airstreams mix.
The DV50 Adroit (Integral CO2 Sensor) unit is designed with a unique triple filter facility including a F7 (ISO ePM1 50%) pollen filter which provides additional protection against invisible, harmful particles and creates an ultra hygienic environment, particularly relevant for those suffering from asthma or other respiratory conditions.
Now including an internal carbon dioxide sensor as standard, the DV50 Adroit (Integral CO2 Sensor) units have both relative humidity and carbon dioxide sensors for a demand-controlled ventilation reducing the energy consumption even more by boosting the unit only when necessary. Extracting indoor humidity and carbon dioxide particulates whereas providing fresh air, helps creating a healthy indoor environment for the residents.
All the supply/exhaust air filters (2 x G4/ISO Coarse 75%, 1 x F7/ISO ePM1 50%) as well as the heat exchanger and fans can be easily maintained via the front access door. To assist this process the maintenance indicator alerts the user for maintenance at a pre-set time interval.
FULLY AUTOMATIC OPERATION
An optional digital controller which incorporates four independent environmental profiles, weekly ventilation programming, and full internet control at home or on the go via the Adroit 'Cloud' for separate fan control for easy commissioning and the optional smart frost protection facility which significantly reduces the energy consumed to protect the heat exchanger from freezing during the winter season.
When fitted with an optional electric post-heater, the unit keeps the indoor air temperature at the required level thanks to the built-in temperature sensors. The unit is also equipped with an automatic, 100% bypass facility which fully isolates the heat exchanger at the pre-defined temperature and helps to effectively maintain a temperate indoor air climate during the summer months.
On-demand ventilation can be achieved by using optional external humidity and CO2 sensors which boost the air volume gradually based on the moisture and occupancy levels in the dwelling. It is also possible to integrate the unit into a Building Management System via the MODBUS or the optional KNX converter to monitor and control unit’s functions by a central control system.
EXTRA PROTECTION AND SAFETY
The DV50 Adroit (Integral CO2 Sensor) is made of a galvanised steel housing unit which is powder coated both internally and externally to ensure high durability and meet the hygiene requirements. The robust double-skin casing includes 20mm insulation, this avoids any thermal bridging which minimises condensate build-up in the unit and significantly absorbs the fan noise.
Also an auto cut-out switch is fitted which immediately cuts the power off as soon as the front cover is removed providing full safety during unit maintenance.
ACCESSORIES:
In addition to a choice of compatible ducting systems a full range of controls, sensors, in-line silencers, floor/wall/ceiling inlet and outlet diffusers are available to complete the installation.
WHAT HAPPENS NEXT?
All centralised mechanical ventilation units require good quality compatible ducting installed to a high standard. To ensure the best results, we recommend the innovative AIRFLEX PRO semi-rigid ducting system to be used with heat recovery ventilation systems.
*Excluding motors. Motor warranty is one year from date of purchase.
CONSULTANT SPECIFICATION
UNIT SPECIFICATON - DV50 ADROIT
The mechanical ventilation with heat recovery unit shall be the DV50 Adroit as manufactured by Airflow, shall be sized as indicated on the drawings and shall be in accordance with the specification.
The unit shall be fully insulated to provide optimum thermal and acoustic performance and shall include a cross counterflow heat exchanger with a 90% thermal efficiency. The heat exchanger shall be protected by a unique triple filter design containing two ISO Coarse>75% (G4) grade filters and one ISO ePM1 (F7) filter on the supply and extract air flow path. The triple filter design shall provide additional protection against harmful particles and shall create ultra-hygienic environment.
The unit shall have low energy consumption EC fans with backward curved impellers design providing a quiet operation and achieving low specific fan power values. The sound power level requirements shall be detailed by the unit's manufacturer and in accordance with the ventilation equipment operation schedule.
The unit shall benefit from a smart frost protection which works in a more energy efficient manner constantly monitoring the heat exchanger conditions and uses the frost heater only when necessary. This significantly reduces the energy consumption and provides more heat recovery throughout the winter season.
As per the Passive House certificate, appropriate measures should be taken to prevent the heat exchanger from getting damaged by frost during extreme winter temperatures (-15C). The heat exchanger frost protection shall be provided by a supply air heater (0.9 kW), which comes built-in as standard with the Adroit EPH unit models (Part number: 90001273EPH – DV50(R) Adroit EPH / 90001274EPH – DV50(L) Adroit EPH).
The unit shall be equipped with an automatic, 100% bypass which totally isolates the heat exchanger so that no air passes through it. This prevents overheating the dwelling in the summer season.
The unit shall be supplied with a 3/4 BSP insulated condensation trap. The unit shall be suitable for 100 mm (4 ports) duct diameter installed at the side entry. The unit shall have the option of being maintained and serviced from outside the dwelling to preserve the building fabric, ensure occupier wellbeing and save energy and shall be installed according to the manufacturer's instruction manual.
The unit shall have a dead man's switch preventing the fans from still running, which will enable the filters to be changed and maintained, avoid particulates matter as could cause damage to the heat recovery cell; also for operational safety reasons.
The unit shall be DV50 Adroit as manufactured by Airflow and shall be listed on the SAP Appendix Q Database PCDB. The Adroit DV50 can be right or left handed as per the manufacturer's technical datasheet.
KEY FEATURES
- For use in dwellings up to 80m2
- Up to 90% thermal efficiency and low SFP
- 'A’ energy rating
- Internet control by smart phone, tablet or PC
- Triple filter design with ePM1(F7) pollen filter
- Automatic, 100% summer by-pass
- Integral humidity and CO2 sensors
- Galvanised steel, double-skin casing with 20 mm insulation
- BMS (Modbus / KNX) connection
- Optional LCD digital controller with four independent environmental profiles
- Optional manual four speed controller
- Optional remote access feature through the Adroit Cloud
- Optional VOC (Volatile Organic Compounds) sensor
- Auto cut-out switch for extra safety
- Optional built-in electric post-heater
- Optional smart frost protection
- Complies with Building Regulations and Passive House
OPERATION
The supply and extract sides shall be positioned as indicated on the project's drawing and shall be in accordance with the ventilation unit's schedule.
The mechanical ventilation with heat recovery unit shall extract stale air from all wet rooms such as bathroom, kitchen, en-suite, W.C., utility rooms and supply fresh warm air to all habitable rooms such as bedrooms and living areas. The incoming air which is the supply air shall be warmed up by the extracted indoor air through the highly efficient heat exchanger. Also, both air flow paths, the extract and supply sides, shall be filtered in order to protect the heat exchanger.
The ventilation unit shall have a variable speed control depending upon the control option chosen in the specification. The unit shall have be easy to commission the supply and extract fans independently having fully variable fan speed control.
CONTROL OPTIONS
The DV50 Adroit unit shall be controlled by one of the following:
- Manual controller
- Adroit digital controller
- Adroit Cloud through the Internet or local network using laptop, smartphone, tablet, etc.
- BMS via LON or KNX through a PC or a central control system
- On-demand ventilation through built-in humidity and CO2 sensors
- Additional external sensors achieving on-demand ventilation
- Switched live signal from light/remote switches
ADROIT DIGITAL CONTROLLER
The Adroit digital controller is compatible with the DV50 Adroit heat recovery unit and shall be an add-on digital controller. This advanced controller comes with commissioning and intuitive end user functions. The DV50 Adroit is controlled via 4 ventilation profiles controls providing the following features:
- 4 ventilation profiles,100% adjustable
- Internet connection available
- Automatic boost function with delay timer
- Filter maintenance reminder via counter clock (standard)
- Heater control for optional post-heater
- Connection to BMS via LON or KNX
- Self diagnostic via fault signal relay
- On-demand control via humidity, CO2 and VOC sensors
- Separate fan control for ease of commissioning
- Weekly ventilation programming allows users to pre-set the ventilation levels scheduled for different days
- Indoor temperature control based on extract air temperature or supply air temperature
Files
- 90001273 ErP Product Fiche
- 90001273 ErP Product Label
- Adroit Residential MVHR Brochure
- DV50 (R) Adroit DWG File
- DV50 Adroit BIM File
- DV50 Adroit Consultant Specification
- DV50 Adroit Data Sheet
- DV50 Adroit Passive House Certificate
- DV50 Adroit Recycling Instructions
- DV50-DV80 Adroit Instruction Manual
- DV50-DV80 Adroit Units Filter Maintenance Guide